Hot Spot IOGP JIP-33 Launch Supplier Questionnaire for S-730 Pressure Relief Valves
What is it?
IOGP JIP-33 has started work on the next revision of their S-730 Pressure Relief Valve Specification by preparing a Supplier Questionnaire for Pressure Relief Valves. They are requesting that any safety valve manufacturer with experience of supplying to S-730 completes an online questionnaire to give feedback on their experience of using the specification. The information will be used to improve the specification during the next revision cycle.
The questionnaire requires information covering sales, technical and quality areas and the link to access it is included in the attachment and repeated here Supplier Questionnaire IOGP S-730 [Maintenance] (office.com). IOGP are requesting that the information is completed by 25/08/23.
Why is it Important?
The current S-730 specification, covering flanged pressure-relief valves, takes the form of a set of requirements that are supplementary to API 526. The document covers basic definitions, design requirements, materials, inspection and testing, identification and preparation for shipment and pressure-temperature tables.
It is intended that the revised specification will be adopted as standard by IOGP members in all flanged pressure-relief valve procurement activities, affecting the future supply of thousands of valves to the upstream oil and gas industry. Therefore, it is important that BVAA members who are pressure -relief valve manufacturers make their voice heard to ensure that the specifications are effective at meeting the needs of the valve manufacturers as well as the end users.
Continuous Improvement - Did we miss anything?
Hot Spots are intended to alert members and provide a brief overview of new standards, activities or procedures that are being introduced in the industry. If there is key information missing that would be helpful, please let us know so that we can improve our future service.
Please Note: This Hotspot is for information purposes, and we invite comments from BVAA members only. Please also note that at time of publication ballots may be closed. For more information, please contact the Secretariat.
BVAA Members: Did you know we have a hotspot tab on the BVAA website? Head over to www.bvaa.org.uk/login-here.asp and log into the member only area. You then need to select ‘Hotspots’ for the latest. For information on how to access the member only area of the website please contact jane@bvaa.org.uk.
Telephone: | 01295 221270 |
Email: | enquiry@bvaa.org.uk |
Website: | www.bvaa.org.uk |
More information on the British Valve and Actuator Association BVAA Member Directory Page |
Search related articles: British Valve and Actuator AssociationIssue 85Technical Hot Spots